EPICARDIAL PACING: TIME RELATED EFFICACY OF ELECTRODES FOLLOWING CARDIAC SURGERY


Article Information

Title: EPICARDIAL PACING: TIME RELATED EFFICACY OF ELECTRODES FOLLOWING CARDIAC SURGERY

Authors: ZAHID PARVEZ, FARID AHMAD CHAUDHARY, AJMAL HASAN NAZQVI, Muniza Saeed

Journal: The Professional Medical Journal (TPMJ)

HEC Recognition History
Category From To
Y 2024-10-01 2025-12-31
Y 2023-07-01 2024-09-30
Y 2022-07-01 2023-06-30
Y 2021-07-01 2022-06-30

Publisher: Independent Medical College, Faisalabad- Pakistan

Country: Pakistan

Year: 2010

Volume: 17

Issue: 1

Language: English

DOI: 10.29309/TPMJ/2010.17.01.1980

Keywords: EfficacyCardiac SurgeryLeft ventricular functionEpicardial Pacing

Categories

Abstract

Placement of epicardial wires on the right atrial and right ventricle surfaces is a routine practice in cardiac surgery. These pacingelectrodes are used for invasive pacing of the myocardium for a variety of emergent and elective conditions postoperatively. There is uncertaintyin actual practice about the optimum time for their removal, and practice varies widely between different institutions. Objectives: To determine thetime related efficacy of these pacing electrodes after cardiac surgery, to find out the optimum time of their removal. Period: July 2008 toOctober 2008. Patients & Methods: 47 patients those underwent coronary artery bypass surgery were prospectively enrolled and evaluatedwith standard 12 lead ECG and ventricle pacing threshold immediately after surgery and on the 5t h postoperative day. The patients were dividedinto two subgroups according to their left ventricle ejection fraction ( > 40% verses < 40%). Results: There was significant difference in theeffective pacing threshold in groupl and 2 on immediate post operative period and on day 5. (P = 0.002 and P = 0.02 respectively) The sensingthreshold immediately after operation and on 5t h post operative day also differed significantly (P = 0.009 in group 1 and 0.02 in group 2) Theeffective VVI* pacing was lost in 17 patients (40.5%) on the 5t h post operative day and comparison of effective pacing threshold in the twogroups showed no significant difference during the same period of time (P = NS). "Ventrculo-ventrical inhibition. Conclusions: The epicardialpacing wires have little usefulness after the fifth postoperative day and should be removed by this time. In addition postoperative pacingthreshold was not affected by the decreased left ventricular function.