DefinePK

DefinePK hosts the largest index of Pakistani journals, research articles, news headlines, and videos. It also offers chapter-level book search.

Effect of 532nm and 589nm Diode-Pumped Solid-State (DPSS) Lasers with Different Doses on Concentration of Total Protein and Albumin in Vitro


Article Information

Title: Effect of 532nm and 589nm Diode-Pumped Solid-State (DPSS) Lasers with Different Doses on Concentration of Total Protein and Albumin in Vitro

Authors: Sabreen Dakhil Yaseen, Jamal Hasan, Mustafa Salih AL Musawi

Journal: Journal of Pakistan Medical Association

HEC Recognition History
Category From To
Y 2024-10-01 2025-12-31
X 2023-07-01 2024-09-30
X 2022-07-01 2023-06-30
X 2021-07-01 2022-06-30
X 2020-07-01 2021-06-30
W 2012-07-01 2020-06-30
X 2011-05-13 2012-06-30
Y 1900-01-01 2005-06-30

Publisher: Pakistan Medical Association.

Country: Pakistan

Year: 2024

Volume: 74

Issue: 10 (Supple-08)

Language: en

DOI: 10.47391/JPMA-BAGH-16-43

Categories

Abstract

Objective: To test the effects of Low-level laser irradiation at 532nm and 589nm with different doses and exposure times on total protein and albumin in blood plasma.
Method:This experimental study was conducted from November 2021 to April 2022 at Mustansiriyah University, Baghdad, Iraq, and comprised blood samples from healthy adults. The samples were stored in tubes containing anticoagulant ethylenediaminetetraacetic acid. Photoradiation was managed using green laser 532nm and yellow laser 589nm diode-pumped solid-state lasers with different doses. For total protein test and albumin test, each sample was divided into 3 equal aliquots. The first was control without radiation, the second was irradiated by a laser at 532nm, and the third was irradiated at 589nm with 30J/cm², 50J/cm², 70J/cm² and 90 J/cm² doses of irradiation. All samples were examined by using a spectrophotometer device. Data was analysed using SPSS 25.
Results: There were 24 samples from healthy adults in all.The most significant difference in total protein concentration occurred at dose 70J/cm² for both wavelengths compared to the controls (p<0.05). When this optimal dose was applied to the albumin test, a clear decrease in the albumin concentration was found for both 532nm and 589nm lasers (p<0.05).
Conclusion: At wavelengths of 532nm and 589nm, the laser light induced processes that caused a reduction in total protein and albumin.
Key Words: Edetic Acid, Lasers, Plasma, Light, Anticoagulants, Albumins


Paper summary is not available for this article yet.

Loading PDF...

Loading Statistics...